With our excellent management, strong technical capability and strict quality control system, we continue to provide our clients with reliable quality, reasonable prices and excellent services. We aim at becoming one of your most reliable partners and earning your satisfaction for telephone cable accessories,telephone cable across the atlantic,telephone cable adapter,we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more detail.
Portable Telecom Visual Fault Locator Pen Type 20km Fiber Optic Cable TesterCable construction details
Number of fiber | 1~4core | |
Central strength member | Material | FRP |
size | 2*0.52mm | |
Outer sheath | material | LSZH |
diameter | 2.0±0.2mm | |
Cable size (Height * width) | 2.0(±0.1) mm × 3.0(±0.2)mm | |
Cable weight | 8.0KG±1KG |
Cable Mechanical characteristic
Items | Description | |
Installation Temperature range(℃) | -20+70 | |
Operation and transport temperature(℃) | -20+70 | |
Min Bending Radius(mm) | Long term | 10D |
Min Bending Radius(mm) |
Short term | 20D |
Min allowable Tensile Strength(N) |
Long term | 150 |
Min allowable Tensile Strength(N) |
Short term | 300 |
Crush Load (N/100mm) | Long term | 1000 |
Crush Load (N/100mm) | short term | 1200 |
Fiber characteristics
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 | ||
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 |
We insist on offering high quality production with good business concept, honest sales and the best and fast service. it will bring you not only the high quality product and huge profit, but the most significant is to occupy the endless market for Portable Telecom Visual Fault Locator Pen Type 20km Fiber Optic Cable Tester, Create Values,Serving Customer!, is the aim we pursue. We sincerely hope that all customers will establish long term and mutually beneficial cooperation with us.If you wish to get more details about our company, Please contact with us now.
–
–