Description
Our products are widely recognized and trusted by users and can meet continuously developing economic and social needs for telephone cable accessories,telephone cable across the atlantic,telephone cable adapter,With the aim of compete with good quality and develop with creativity and the service principle of take customers demand as orientation, we will earnestly provide qualified products and good service for domestic and international customers.
PON Fiber Optical Power Meter PON Power Meter Wavelength 1310 1490 1550nm Fiber Optic TesterCable construction details
Number of fiber | 1~4core | |
Central strength member | Material | FRP |
size | 2*0.52mm | |
Outer sheath | material | LSZH |
diameter | 2.0±0.2mm | |
Cable size (Height * width) | 2.0(±0.1) mm × 3.0(±0.2)mm | |
Cable weight | 8.0KG±1KG |
Cable Mechanical characteristic
Items | Description | |
Installation Temperature range(℃) | -20+70 | |
Operation and transport temperature(℃) | -20+70 | |
Min Bending Radius(mm) | Long term | 10D |
Min Bending Radius(mm) |
Short term | 20D |
Min allowable Tensile Strength(N) |
Long term | 150 |
Min allowable Tensile Strength(N) |
Short term | 300 |
Crush Load (N/100mm) | Long term | 1000 |
Crush Load (N/100mm) | short term | 1200 |
Fiber characteristics
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 | ||
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 |
PON Fiber Optical Power Meter PON Power Meter Wavelength 1310 1490 1550nm Fiber Optic Tester, Welcome to build the well and long standing business relationships with our company to create a glorious future together. customers, satisfaction is our eternal pursuit
–
–