The company upholds the philosophy of ,Be No.1 in quality, be rooted on credit and trustworthiness for growth ,, will continue to serve old and new customers from home and overseas whole-heatedly for addressable fire alarm cable,afc fire alarm cable,aquaseal fire alarm cable, Competitive price with high quality and satisfying service make us earned more customers.we wish to work with you and seek common development.
Fire Alarm Cable 18 AWG, 16 AWG, 14 AWG & 12 AWG 2 & 4 Solid Copper Conductors FPLP FT6 Shielded 1000\’ Red
CABLE CONSTRUCTION
Conductor
|
Screen
|
Sheath Color
|
Solid bare Copper
IEC 60228 class 1 |
Aluminium laminated polyester tape | Red ( RAL 3000) or White |
Insulation
|
Earth Wire
|
Standard Packing Mode
|
Fire resistant silicon rubber (HD 22.1, BS 7655 EI2) | Tinned Copper to IEC 60228 Solid 0.80mm |
100 mtr / Plywood Reel 500 mtr / Plywood Reel (optional)
|
Insulation Colour
|
Sheath
|
|
2 Core: blue/brown | HFFR EN 50290-2,BS 7655 LTS1/LTS3 VDE 0207 |
ELECTRICAL & MECHANICAL CHARACTERISTICS
Flame Tests | Insulation Integrity | Smoke Density | Corrosive Gases Measurement |
IEC 60332-1
IEC 60332-3-24 EN 50266-2-4 |
IEC 60331
BS 6387 C, W, Z Cat,C fire @950Co – 180 min Cat,W fire and water @ 650Co -15 +15 min Cat,Z fire and mechanical shocks @ 950Co – 15 min. EN 50200 PH 120 EN 50200(Annex E) |
IEC 61034
EN 50268 HD 606 |
IEC 60754-2
EN 50267 |
Properties Value | ||
1.5 mm2 | 2.5 mm2 | |
Max. Conductor Resistant @ 20 ºC | 12.0Ω/km | 7.4 Ω/km |
Min. Insulation Resistant @ 0 ºC | 200 MΩxkm | |
Operating Voltage | 300/500 V | |
Test Voltage | 2000 V | |
Temperature Rating (Fixed) | -30 ºC to + 90 ºC | |
Temperature Rating (Flexing) | -5 ºC to + 60 ºC | |
Min. Bend Radius (Fixed) | 8 x D | |
Min. Bend Radius (Flexing) | 15 x D |
FIRE RESISTANT CABLE PH 120 SFR INSULATION
PHYSICAL INFORMATION
Nom. Cond. Cross-Sect. mm2 | Conductor Size no./mm | Earth Wire Size no./mm | Cable diameter mm (±5 %) | Weight Kg/km |
2 x 1.5 | 1/1.37 | 1/0.80 | 8.00 | 98.0 |
2 x 2.5 | 1/1.75 | 1/0.80 | 9.70 | 148.0 |
Assume full responsibility to meet all demands of our clients; achieve continuous advancements by promoting the growth of our clients; become the final permanent cooperative partner of clients and maximize the interests of clients for Fire Alarm Cable 18 AWG, 16 AWG, 14 AWG & 12 AWG 2 & 4 Solid Copper Conductors FPLP FT6 Shielded 1000\’ Red,items won certifications with the regional and international primary authorities. For far more detailed information, please contact us!
–
–