We aim to create more value for our customers with our rich resources, advanced machinery, experienced workers and excellent services for telephone cable electric shock,telephone cable enclosures,telephone cable engineers, Our company will continue to adhere to the superior quality, reputable, the user first principle wholeheartedly. We warmly welcome friends from all walks of life to visit and give guidance, work together and create a brilliant future!
CAT 6 ftp NETWORK lan PATCH CORD/ cableCable construction details :
Number of fiber | 24-144core | |||||||
Filling rope | 4-0 | |||||||
Moisture Barrier | Water blocking system | |||||||
Central strength member | material | Steel wire/FRP | ||||||
size | 1.4mm | |||||||
Tube-filling | Tube filling compoun | |||||||
Inner sheath | material | PE/HDPE | ||||||
diameter | 2.0mm | |||||||
Loose tube | material | PBT | ||||||
diameter | Ф2.2(outer/inner) | |||||||
Outer armored | material | Aluminium tape/Corrugated steel tape | ||||||
Outer sheath | material | PE/HDPE | ||||||
diameter | 1.7±0.2mm |
Fiber color
Number of fiber per tube 8cores |
1 | 2 | 3 | 4 | 5 | 6 |
Blue | Orange | Green | Brown | Grey | White | |
7 | 8 | 9 | 10 | 11 | 12 | |
Red | Black | Yellow | Violet | Pink | Aqua | |
Color 13~24 will be marked with a black tracer. For black color no need marked black tracer, will use nature color instead. |
Cable Mechanical characteristic
core | Cable diameter | weight | |||||
24 core to 60core | 12.0±0.2mm | 150±10kg/km | |||||
62 core to 72core | 12.5±0.5mm | 210±10kg/km | |||||
74 core to 96core | 14.1±0.5mm | 230±10kg/km | |||||
98 core to 144core | 16.5±0.5mm | 250±10kg/km | |||||
Min Bending Radius(mm) | Long term | 10D | |||||
Min Bending Radius(mm) |
Short term | 20D | |||||
Min allowable Tensile Strength(N) |
Long term | 3000 | |||||
Min allowable Tensile Strength(N) |
Short term | 4000 | |||||
Min. Allowable Crush Load (N/100mm) | Long term | 1000 | |||||
Min. Allowable Crush Load (N/100mm) | short term | 3000 | |||||
Operation temperature (℃) |
-40+70 | ||||||
Installation temperature(℃) |
-15+60 | ||||||
Storage temprature (℃) |
-40+70 |
Fiber characteristic
Fiber style | Unit | SM G652 |
SM G652D |
MM 50/125 |
MM 62.5/125 |
MM OM3-300 |
|
condition | nm | 1310/1550 | 1310/1550 | 850/1300 | 850/1300 | 850/1300 | |
attenuation | dB/km | ≤ | ≤ | ≤ | ≤3.0/1.0 | ≤3.0/1.0 | |
0.36/0.23 | 0.34/0.22 | 3.0/1.0 | —- | —- | |||
Dispresion | 1550nm | Ps/(nm*km) | —- | ≤18 | —- | —- | Dispresion |
1625nm | Ps/(nm*km) | —- | ≤22 | —- | —- | ||
Bandwith | 850nm | MHZ.KM | —- | —- | ≧400 | ≧160 | Bandwith |
1300nm | MHZ.KM | —- | —- | ≧800 | ≧500 | ||
Zero dispersion wavelength | nm | 1300-1324 | ≧1302, ≤1322 |
—- | —- | ≧ 1295, ≤1320 |
|
Zero dispresion slope | nm | ≤0.092 | ≤0.091 | —- | —- | —- | |
PMD Maximum Individual Fibr | ≤0.2 | ≤0.2 | —- | —- | ≤0.11 | ||
PMD Design Link Value | Ps(nm2*k m) |
≤0.12 | ≤0.08 | —- | —- | —- | |
Fibre cutoff wavelength λc | nm | ≧ 1180, ≤1330 |
≧1180, ≤1330 |
—- | —- | —- | |
Cable sutoff wavelength λcc |
nm | ≤1260 | ≤1260 | —- | —- | —- | |
MFD | 1310nm | um | 9.2+/-0.4 | 9.2+/-0.4 | —- | —- | —- |
1550nm | um | 10.4+/-0.8 | 10.4+/-0.8 | —- | —- | —- | |
Numerical Aperture(NA) |
—- | —- | 0.200+/ -0.015 |
0.275+/-0. 015 |
0.200+/-0 .015 |
||
Step(mean of bidirectional measurement) |
dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | |
Irregularities over fiber length and point |
dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 |
Dicontinuity | |||||||
Difference backscatter coefficient |
dB/km | ≤0.05 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | |
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ||||
Core dimater | um | 50+/-1.0 | 62.5+/-2.5 | 50+/-1.0 | |||
Cladding diameter | um | 125.0+/-0.1 | 125.0+/-0.1 | 125.0+/-0.1 | 125.0+/-0.1 | 125.0+/-0.1 | |
Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
Coating diameter | um | 242+/-7 | 242+/-7 | 242+/-7 | 242+/-7 | 242+/-7 | |
Coating/chaffinch concentrically error |
um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
Core/cladding conentricity error | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | |
Curl(radius) | um | ≤4 | ≤4 | —- | —- | —- |
Package
1.Packing material: Wooden drum | |||||||
2.Packing length: standard length of cable shall be 2 km. Other cable length is also availabler | |||||||
if required by custome |
Fiber style | Unit | SM G652D | MM 50/125 | MM 62.5/125 | ||||
Condition | mm | 1310/1550 | 850/1300 | 850/1300 | ||||
Attenuation | dB/km | ≤0.36/0.22 | ≤3.0/1.0 | ≤3.0/1.0 | ||||
Cladding diameter | um | 125±1 | 125±1 | 125±1 | ||||
Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ||||
Coating diameter | um | 242±7 | 242±7 | 242±7 |
We are proud of the high customer satisfaction and wide acceptance due to our persistent pursuit of high quality both on product and service for CAT 6 ftp NETWORK lan PATCH CORD/ cable, Create Values,Serving Customer!, is the aim we pursue. We sincerely hope that all customers will establish long term and mutually beneficial cooperation with us.If you wish to get more details about our company, Please contact with us now.
–
–