Our company puts emphasis on the management, the introduction of talented personnel, and the construction of staff building, trying hard to improve the quality and liability consciousness of staff members. Our company successfully attained IS9001 Certification and European CE Certification of telephone cable electric shock,telephone cable enclosures,telephone cable engineers,We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
SFTP CAT7 patch cord cableCable construction details :
Number of fiber | 24-144core | |||||||
Filling rope | 4-0 | |||||||
Moisture Barrier | Water blocking system | |||||||
Central strength member | material | Steel wire/FRP | ||||||
size | 1.4mm | |||||||
Tube-filling | Tube filling compoun | |||||||
Inner sheath | material | PE/HDPE | ||||||
diameter | 2.0mm | |||||||
Loose tube | material | PBT | ||||||
diameter | Ф2.2(outer/inner) | |||||||
Outer armored | material | Aluminium tape/Corrugated steel tape | ||||||
Outer sheath | material | PE/HDPE | ||||||
diameter | 1.7±0.2mm |
Fiber color
Number of fiber per tube 8cores |
1 | 2 | 3 | 4 | 5 | 6 |
Blue | Orange | Green | Brown | Grey | White | |
7 | 8 | 9 | 10 | 11 | 12 | |
Red | Black | Yellow | Violet | Pink | Aqua | |
Color 13~24 will be marked with a black tracer. For black color no need marked black tracer, will use nature color instead. |
Cable Mechanical characteristic
core | Cable diameter | weight | |||||
24 core to 60core | 12.0±0.2mm | 150±10kg/km | |||||
62 core to 72core | 12.5±0.5mm | 210±10kg/km | |||||
74 core to 96core | 14.1±0.5mm | 230±10kg/km | |||||
98 core to 144core | 16.5±0.5mm | 250±10kg/km | |||||
Min Bending Radius(mm) | Long term | 10D | |||||
Min Bending Radius(mm) |
Short term | 20D | |||||
Min allowable Tensile Strength(N) |
Long term | 3000 | |||||
Min allowable Tensile Strength(N) |
Short term | 4000 | |||||
Min. Allowable Crush Load (N/100mm) | Long term | 1000 | |||||
Min. Allowable Crush Load (N/100mm) | short term | 3000 | |||||
Operation temperature (℃) |
-40+70 | ||||||
Installation temperature(℃) |
-15+60 | ||||||
Storage temprature (℃) |
-40+70 |
Fiber characteristic
Fiber style | Unit | SM G652 |
SM G652D |
MM 50/125 |
MM 62.5/125 |
MM OM3-300 |
|
condition | nm | 1310/1550 | 1310/1550 | 850/1300 | 850/1300 | 850/1300 | |
attenuation | dB/km | ≤ | ≤ | ≤ | ≤3.0/1.0 | ≤3.0/1.0 | |
0.36/0.23 | 0.34/0.22 | 3.0/1.0 | —- | —- | |||
Dispresion | 1550nm | Ps/(nm*km) | —- | ≤18 | —- | —- | Dispresion |
1625nm | Ps/(nm*km) | —- | ≤22 | —- | —- | ||
Bandwith | 850nm | MHZ.KM | —- | —- | ≧400 | ≧160 | Bandwith |
1300nm | MHZ.KM | —- | —- | ≧800 | ≧500 | ||
Zero dispersion wavelength | nm | 1300-1324 | ≧1302, ≤1322 |
—- | —- | ≧ 1295, ≤1320 |
|
Zero dispresion slope | nm | ≤0.092 | ≤0.091 | —- | —- | —- | |
PMD Maximum Individual Fibr | ≤0.2 | ≤0.2 | —- | —- | ≤0.11 | ||
PMD Design Link Value | Ps(nm2*k m) |
≤0.12 | ≤0.08 | —- | —- | —- | |
Fibre cutoff wavelength λc | nm | ≧ 1180, ≤1330 |
≧1180, ≤1330 |
—- | —- | —- | |
Cable sutoff wavelength λcc |
nm | ≤1260 | ≤1260 | —- | —- | —- | |
MFD | 1310nm | um | 9.2+/-0.4 | 9.2+/-0.4 | —- | —- | —- |
1550nm | um | 10.4+/-0.8 | 10.4+/-0.8 | —- | —- | —- | |
Numerical Aperture(NA) |
—- | —- | 0.200+/ -0.015 |
0.275+/-0. 015 |
0.200+/-0 .015 |
||
Step(mean of bidirectional measurement) |
dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | |
Irregularities over fiber length and point |
dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 |
Dicontinuity | |||||||
Difference backscatter coefficient |
dB/km | ≤0.05 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | |
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ||||
Core dimater | um | 50+/-1.0 | 62.5+/-2.5 | 50+/-1.0 | |||
Cladding diameter | um | 125.0+/-0.1 | 125.0+/-0.1 | 125.0+/-0.1 | 125.0+/-0.1 | 125.0+/-0.1 | |
Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
Coating diameter | um | 242+/-7 | 242+/-7 | 242+/-7 | 242+/-7 | 242+/-7 | |
Coating/chaffinch concentrically error |
um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
Core/cladding conentricity error | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | |
Curl(radius) | um | ≤4 | ≤4 | —- | —- | —- |
Package
1.Packing material: Wooden drum | |||||||
2.Packing length: standard length of cable shall be 2 km. Other cable length is also availabler | |||||||
if required by custome |
Fiber style | Unit | SM G652D | MM 50/125 | MM 62.5/125 | ||||
Condition | mm | 1310/1550 | 850/1300 | 850/1300 | ||||
Attenuation | dB/km | ≤0.36/0.22 | ≤3.0/1.0 | ≤3.0/1.0 | ||||
Cladding diameter | um | 125±1 | 125±1 | 125±1 | ||||
Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ||||
Coating diameter | um | 242±7 | 242±7 | 242±7 |