To constantly improve the management system by virtue of the rule of ,sincerely, good faith and quality are the base of enterprise development ,, we widely absorb the essence of related products internationally, and constantly develop new products to meet the demands of customers for telephone cable accessories,telephone cable across the atlantic,telephone cable adapter, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more detail
PON Fiber Optical Power Meter PON Power Meter Wavelength 1310 1490 1550nm Fiber Optic TesterCable construction details
Number of fiber | 1~4core | |
Central strength member | Material | FRP |
size | 2*0.52mm | |
Outer sheath | material | LSZH |
diameter | 2.0±0.2mm | |
Cable size (Height * width) | 2.0(±0.1) mm × 3.0(±0.2)mm | |
Cable weight | 8.0KG±1KG |
Cable Mechanical characteristic
Items | Description | |
Installation Temperature range(℃) | -20+70 | |
Operation and transport temperature(℃) | -20+70 | |
Min Bending Radius(mm) | Long term | 10D |
Min Bending Radius(mm) |
Short term | 20D |
Min allowable Tensile Strength(N) |
Long term | 150 |
Min allowable Tensile Strength(N) |
Short term | 300 |
Crush Load (N/100mm) | Long term | 1000 |
Crush Load (N/100mm) | short term | 1200 |
Fiber characteristics
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 | ||
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 |
As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for PON Fiber Optical Power Meter PON Power Meter Wavelength 1310 1490 1550nm Fiber Optic Tester, Standing still today and looking into the future, we sincerely welcome customers all over the world to cooperate with us.
–
–