Description
The company upholds the philosophy of ,Be No.1 in quality, be rooted on credit and trustworthiness for growth ,, will continue to serve old and new customers from home and overseas whole-heatedly for telephone cable accessories,telephone cable across the atlantic,telephone cable adapter, We sincerely welcome overseas customers to consult for the long-term cooperation and the mutual development.We strongly believe that we can do better and better.
GTF3304N Fiber Optic Cable Fault Locator, Fiber Ranger,Telecom Fault TesterCable construction details
Number of fiber | 1~4core | |
Central strength member | Material | FRP |
size | 2*0.52mm | |
Outer sheath | material | LSZH |
diameter | 2.0±0.2mm | |
Cable size (Height * width) | 2.0(±0.1) mm × 3.0(±0.2)mm | |
Cable weight | 8.0KG±1KG |
Cable Mechanical characteristic
Items | Description | |
Installation Temperature range(℃) | -20+70 | |
Operation and transport temperature(℃) | -20+70 | |
Min Bending Radius(mm) | Long term | 10D |
Min Bending Radius(mm) |
Short term | 20D |
Min allowable Tensile Strength(N) |
Long term | 150 |
Min allowable Tensile Strength(N) |
Short term | 300 |
Crush Load (N/100mm) | Long term | 1000 |
Crush Load (N/100mm) | short term | 1200 |
Fiber characteristics
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 | ||
Fiber style | Unit | SM
G652D |
SM
G657A1 |
SM
G657A2 |
||
condition | nm | 1310/1550 | 1310/1550 | 1310/1550 | ||
attenuation | dB/km | ≤0.36/0.23 | ≤3.5/0.21 | ≤3.5/0.21 | ||
Dispersion | 1310nm | Ps/(nm*km) | ≤18 | ≤18 | ≤18 | |
1550nm | Ps/(nm*km) | ≤22 | ≤22 | ≤22 | ||
Zero dispersion wavelength | nm | 1312±10 | 1312±10 | 1300-1324 | ||
Zero dispersion slope | ps/(nm²×Km) | ≤0.091 | ≤0.090 | ≤0.092 | ||
PMD Maximum Individual Fiber | [ps/√km] | ≤0.2 | ≤0.2 | ≤0.2 | ||
PMD Design Link Value | ps/(nm²×Km) | ≤0.08 | ≤0.08 | ≤0.08 | ||
Fiber cutoff wavelength λc | nm | ≧1180,≤1330 | ≧1180,≤1330 | ≧1180,≤1330 | ||
Cable cutoff wavelength λcc | nm | ≤1260 | ….. | ….. | ||
MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | 9.8±0.4 | |
1550nm | um | 10.4±0.8 | 10.1±0.5 | 9.8±0.5 | ||
Step(mean of bidirectional measurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Irregularities over fiber length and point discontinuity | dB | ≤0.05 | ≤0.05 | ≤0.05 | ||
Difference backscatter coefficient | dB/km | ≤0.03 | ≤0.03 | ≤0.03 | ||
Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | ||
Cladding diameter | um | 125.0±0.1 | 124.8±0.1 | 124.8±0.1 | ||
Cladding non-circularity | % | ≤1.0 | ≤0.7 | ≤0.7 | ||
Coating diameter | um | 242±7 | 242±7 | 242±7 | ||
Coating/chaffinch concentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ||
Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ||
Core/cladding concentricity error | um | ≤0.6 | ≤0.5 | ≤0.5 | ||
Curl(radius) | um | ≥4 | ≥4 | ≥4 |
We always believe that one, s character decides products, quality, the details decides products, quality ,with the REALISTIC,EFFICIENT AND INNOVATIVE team spirit for GTF3304N Fiber Optic Cable Fault Locator, Fiber Ranger,Telecom Fault Tester, Competitive price with high quality and satisfying service make us earned more customers.we wish to work with you and seek common development.
–
–